UL Online Certifications Directory

XCFR2.E62806
Terminal Blocks - Component

Page Bottom


Terminal Blocks - Component


See General Information for Terminal Blocks - Component

MARATHON SPECIAL PRODUCTS CORPE62806
13300 VAN CAMP RD
PO BOX 468
BOWLING GREEN, OH 43402 USA
Model
No.
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
132X122 Al-Cu 1 61 600 200 C 2(125),5,#
132X422 Al-Cu 1 61 600 200 C 2(125),5,#

X - The letter X is replaced by 1, 2 or 3 to indicate the number of poles.

# Unique condition of acceptability - The terminal blocks are provided with threaded studs and are intended for use with prepared conductors. Suitability for the tabulated voltage, current and torque ratings must be conducted in the end use application.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V
A
Al Cu

UG

CA
132X 474 +, ++ Al-Cu 2 + 600 135 175 C 2(125)
132X 570 +, ++ Al-Cu 2 + 600 135 175 C 2(125), 6 (16 x 12 x 6), #
132X 572 +, ++ Al-Cu 2 + 600 135 175 C 2(125), 6 (16 x 12 x 6), #
132X 574 +, ++ Al-Cu 2 + 600 135 175 C 2(125), 6 (16 x 12 x 6)
132X 580 +, ++ Al-Cu 2 + 600 135 175 C 2(125), 6 (16 x 12 x 6), #
132X 970 +, ++ Cu 2 + 600 — 175 C 2(125), 6 (16 x 12 x 6), #
132X 972 +, ++ Cu 2 + 600 — 175 C 2(125), 6 (16 x 12 x 6)
133X126 ± Al-Cu 2 ± 600 310 C 2(125), 4
133X270 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X271 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X272 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X273 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X280 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X281 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X305 ± Al-Cu 2 ± 600 350 C 2(125), 4
133X320 ± Al-Cu 2 ± 600 510 C 2(125), 6 (16 x 12 x 6), 4
133X360 ± Al-Cu 2 ± 600 420 C 2(125), 4, 6 (16 x 12 x 6),#
133X552 ± Al-Cu 2 ± 600 335 C 2(125), 4, 6 (16 x 12 x 6), #
133X554 ± Al-Cu 2 ± 600 310 C 2(125), 4, 6 (16 x 12 x 6), #
133X555 ± Al-Cu 2 ± 600 350 C 2(125), 4, 6 (16 x 12 x 6), #
133X558 ± Al-Cu 2 ± 600 310 C 2(125), 4
133X559 ± Al-Cu 2 ± 600 310 C 2(125), 6 (16 x 12 x 6), 4
133X563 ± Al-Cu 1 ± 600 310 C 2(125), 5
133X564 ± Al-Cu 1 ± 600 310 C 2(125), 5
133X565 ± Al-Cu 2 ± 600 420 C 2(125), 4
133X575 ± Al-Cu 2 ± 600 420 C 2(125), 4
133X585 ± Al-Cu 2 ± 600 420 C 2(125), 4, 6 (16 x 12 x 6),#
133X587 ± Al-Cu 2 ± 600 380 C 2(125), 4, 6 (16 x 12 x 6), #
133X588 ± Al-Cu 2 ± 600 420 C 2(125), 4, 6 (16 x 12 x 6), #
133X595 ± Al-Cu 2 ± 600 420 C 2(125), 4, 6 (16 x 12 x 6), #
133X596 ± Al-Cu 2 ± 600 510 C 2(125), 4, 6 (16 x 12 x 6),#
133X597 ± Al-Cu 2 ± 600 510 C 2(125), 4, 6 (16 x 12 x 6),#
133X598 ± Al-Cu 2 ± 600 510 C 2(125), 4
133X953 ± Al-Cu 2 ± 600 380 C 2(125), 4, 6 (16 x 12 x 6),#
133X955 ± Al-Cu 2 ± 600 350 C 2(125), 4, 6 (16 x 12 x 6), #

X-The letter X is replaced by 1,2 or 3 to indicate the number of poles.

# Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered.

+ See Report for wire range and torque values.

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
143X120 (1)1/0-14, ++ Al-Cu 2 50 600 150 C 2(150)
143X121 (1)1/0-14, ++ Cu 2 50 600 150 C 2(150)
(1)1/0-18, ++ Cu 2 35 600 150 C 2(150)
143X123 (1)250-6, ++ Al-Cu 2 275 600 255 C 2(150)
143X124 (1)250-6, + Cu 2 375 600 255 C 2(150)
143X126 (1)350-6, ++ Al-Cu 2 275 600 310 C 2(150)
143X401 (1)350-6, ++ Al-Cu 2 275 600 310 C 2(150)
143X552 (1)400-6, ++ Al-Cu 2 275 600 335 C 2(150), 6 (16 x 12 x 6), #
143X553 (1)400-6, ++ Al-Cu 2 275 600 350 C 2(150), 6 (16 x 12 x 6), #
143X554 ± Al-Cu 2 ± 600 310 C 2(150), 6 (16 x 12 x 6)
143X555 (2)2/0-14, ++ Al-Cu 2 120 600 350 C 2(150), 6 (16 x 12 x 6)
143X585 (1)2/0-14 Al 2 120 600 125 C 2(150)
++ Cu 2 120 600 150 C 2(150)
143X587 (1)500-4, ++ Al-Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
143X953 (1)500-6, ++ Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
143X955 (2)2/0-14, ++ Cu 2 120 600 350 C 2(150), 6 (16 x 12 x 6), #
144X123 (1)250-6, ++ Al-Cu 2 275 600 255 C 2(150), 6 (16 x 12 x 6)
144X126 (1)350-6, ++ Al-Cu 2 275 600 310 C 2(150), 6 (16 x 12 x 6)
144X401 (1)400-6, ++ Al-Cu 2 275 600 335 C 2(150)
144X551 (1)500-4, ++ Al-Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
144X557 (1)600-4, ++ Al-Cu 2 500 600 420 C 2(150), 6 (16 x 12 x 6), #
144X560 (1)400-6, ++ Al-Cu 2 275 600 335 C 2(150), 6 (16 x 12 x 6), #
145X129 (2)350-4, ++ Al-Cu 2 275 600 620 C 2(150)
145X282 2/0-6 Al-Cu 2 120 600 760-Cu, 620-Al C 2(150)
8 Al-Cu 2 40
10-14 Cu 2 35
145X301 (2)500-6, ++ Al-Cu 2 375 600 760 C 2(150)
145X411 (2)600-2, ++ Al-Cu 2 500, 600 840 Cu, C 2(150)
(4)4-14, 35, 860 Al
(3)3/0-6 120
145X408 (2)500-6, ++ Cu 2 375 600 760 C 2(150)
Al 2 375 600 620 C 2(150)
145X552 (1)500-4, ++ Al-Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
145X579 (2)500-4, ++ Al-Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
145X586 (2)500-6, ++ Al-Cu 2 375 600 760 C 2(150), 6 (16 x 12 x 6), #
145X587 (1)500-6, ++ Al-Cu 2 375 600 380 C 2(150)
(1)350-4, ++ Al-Cu 2 275 600 310 C 2(150)
145X592 (2)500-6, ++ Al-Cu 2 375 600 760 C 2(150), 6 (16 x 12 x 6), #
145X594 (1)500-4, ++ Al-Cu 2 375 600 380 C 2(150), 6 (16 x 12 x 6), #
145X615 (4)600-2, ++ Al-Cu 2 500 600 * C 2(150)
145X986 (2)500-4, ++ Cu 2 375 600 760 C 2(150), 6 (16 x 12 x 6), #
145X992 (2)500-4, ++ Cu 2 375 600 760 C 2(150), 6 (16 x 12 x 6), #

X-The letter X is replaced by 1, 2 or 3 to indicate number of poles.

+ - See report for flexible stranded wire class acceptability.

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded copper wire.

# Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered

(*)-Current rating of 1680A when utilizing copper wire, 1360A when utilizing aluminum wire

+ See Report for wire range and torque valves.

Series
No.
Wire
Range
Wire
Type

FW
TQ
In.-Lb

V

A

UG

CA
15XX, 16XX(1) 10-22 Cu 2 20 600 75 C 2(150),#,4
17XXSTD, 17XXSC, 17XXDJ 10-18 Cu 2 20 600 30 C 2(125)
17XXSTD, 17XXST 4-18 Cu 2 20 600 75 C 2(125),5
17XXSP, 17XXSPSE 10-22 Cu 2 20 600 30 C 2(125)

(1)May be followed by DJ, DJSV, H, SC, ST, STD. The letters XX are replaced by 02, 03, 04, 06, 08 or 12.

#Unique condition of acceptability-These devices are rated for a maximum of 75A per pole when utilizing a stud type terminal ("ST" option). However, the pressure plate type terminal ("SP" option) is rated 30A.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
6H38, 6N38, 14-16 Cu 2 600 20 C 2(105)
6H716, 6N716(5) 12-20 Sol., Cu 2 9 600 20 C 2(105)
12-22 Str.
6H38, 6N38, 12-22 Cu 2 20 600 25 C 2(105)
6H716, 6N716(3) 12-20 Sol., Cu 2 9 600 25 C 2(105)
12-22 Str.
H-0460 (2)4-14, ++ Al-Cu 2 (4) 600 85 C 2(70)

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.

(5)May be followed by -S-C, -S-F.

(3)May be followed by -SP-C, -SP-F.

(4)For wire range 4-6, 45 in.-lb; wire range 8, 40 in.-lb; wire range 10-14, 35 in.-lb.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
141X100 4-16, ++ Cu 2 + 600 70 C 2(110),#
4-12 Al 2 + 600 55 C 2(110),#
141X200, -201, 2-14, ++ Cu 2 + 600 115 C 2(110)
-202, -203 2-12 Al 2 + 600 90 C 2(110)
141X204 2-14, ++ Cu 2 + 600 20 C 2(110), 6 (16 x 12 x 6)#
2-12 Al 2 + 600 C 2(110),#
141X205, -300, 2-14, ++ Cu 2 + 600 115 C 2(110), 6 (16 x 12 x 6), ##
-301, -400 2-12 Al 2 + 600 90 C 2(110)
141X401 2-14, ++ Cu 2 + 600 90 C 2(110)
2-12 Al 2 + 600 75 C 2(110)
141X402 2-14, ++ Cu 2 + 600 115 C 2(110)
2-12 Al 2 + 600 90 C 2(110)
141X403 2-14, ++ Cu 2 + 600 60 C 2(110)
2-12 Al 2 + 600 50 C 2(110)

X-The letter X is replaced by 1, 2, 3 or 4 to indicate number of poles.

+-Products evaluated to to UL486E which allows for reduced torque values. See report for torque valves.

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.

#Unique condition of acceptability-These models are intended to be wired with crimped type fork or ring terminals for wires larger than 10 AWG.

## Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
140X405 2/0-14 CU-Al 2 (1) 250 175 A 2(150)

X-The letter X is replaced by 1, 2 or 3 to indicated number of poles.

(1)For wire size 3/0-6, 120 in.-lb; wire size 8, 40 in.-lb; wire size 10-14, 35 in.-lb.

Model
No.
Wire
Type

FW
TQ
(In.-Lb)

V

A

UG

CA
142X122 Al-Cu 2 Line - 61
Load - 61
600 200 C 2(150),#
142X123 Al-Cu 1 Line - 50
Load - 50
600 200 C 2(150),5,#
142X411 Al-Cu, ++ 2 Line - 2/0-6 AWG - 120
8 AWG - 40
10-14 AWG - 35
Load - 35
600 175 C 2(150),#
142X553 Al-Cu, ++ 2 Line - 2/0-6 AWG - 120
8 AWG - 40
10-14 AWG - 35
Load - 35
600 175 C 2(150),#
142X574 Al-Cu, ++ 2 Line - 2/0-6 AWG - 120
8 AWG - 40
10-14 AWG - 35
Load - 35
600 175 C 2(150),#, 6 (16 x 12 x 6), ##
143X122 Al-Cu 1 Line - 192
Load - 192
600 230 C 2(150),#
143X559 Al-Cu 2 Line - 275
Load - 192
600 310 C 2(150), 6 (16 x 12 x 6)#
Al-Cu 1 Line - 275
Load - 192
600 350 C 2(150),5,#
143X561 Al-Cu 2 Line - 192
Load - 61
600 230 C 2(150),5,#
143X563 Al-Cu 2 Line - 192
Load - 192
600 230 C 2(150),5,#
143X590 Al-Cu, ++ 2 Line - 2/0-6 AWG - 120
8 AWG - 40
10-14 AWG - 35
Load - 35
600 175 C 2(150),#
144X122 Al-Cu 1 Line - 192
Load - 61
600 260 C 2(150),5,#
144X553 Al-Cu 1 Line - 192
Load - 192
600 230 C 2(150),5,#
144X569 Al-Cu, ++ 2 Line - 375
Load - 61
600 380 C 2(150),#
144X575 Al-Cu, ++ 2 Line - 375
Load - 192
600 380 C 2(150),#
144X579 Al-Cu 1 Line - 192
Load - 61
600 230 C 2(150),5,#
144X614 Al-Cu 1 Line - 192
Load - 192
600 840 C 2(150),5,#
145X570 Al-Cu 1 Line - 192
Load - 61
600 360 C 2(150),5,#
145X573 Al-Cu 1 Line - 192
Load - 192
600 360 C 2(150),5,#
145X583 Al-Cu 1 Line - 192
Load - 61
600 360 C 2(150),5,#
145X596 Cu 2 Line - 600
Load - 192
600 545 C 2(150),#
Al 2 Line - 600
Load - 192
600 445 C 2(150),#
145X599 Al-Cu, ++ 2 Line - 375
Load - 192
600 760 C 2(150), 6 (16 x 12 x 6),#
145X606 Al-Cu 1 Line - 422
Load - 422
600 410 C 2(150),5,#
145X610 Al-Cu, ++ 2 Line - 375
Load - 422
600 760 C 2(150),#
145X611 Al-Cu 1 Line - 422
Load - 422
600 410 C 2(150),5,#
145X613 Al-Cu 1 Line - 192
Load - 192
600 475 C 2(150),5,#
145X614 Al-Cu 1 Line - 422
Load - 422
600 670 C 2(150),5,#
145X616 Cu 1 Line - 422
Load - 422
600 600 C 2(150),5,#
133X601 Al-Cu 1 Line - 422
Load - 422
600 410 C 2(150),5,#

#Unique conditions of acceptability — These terminal blocks are provided with threaded studs or threaded holes. Suitability for the tabulated voltage and Current ratings i.e. Listing and dielectric tests must be conducted in the end-use application.

## Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered

++ - These terminal blocks are acceptable for Class G, H, I, K and DLO flexible stranded copper wire. See report for wire sizes and torques.


Cat. No.+
Wire
Range
Wire
Type

FW
TQ
In.-Lb

V

A

UG

CA
3XX, 3XX-1, 10-14 Cu 2 600 30 C 2(150)
3XXSB, 3XX-IMP,
672-GP-XX,
672-GP-XX-RSXXX-EPXXX
3XXS, 3XX-HS, 10-14 Cu 1 600 30 C 2(150),#
3XX-LWW, 3XX-F1,
3XX-F2, 3XX-F3,
3XX-HF1, 3XX-HF2,
3XX-HF3, 3XX-L,
3XX-NS, 3XX-F1-F2,
3XX-F1-F3, 3XX-F2-F3,
3XX-F1-F2-F3, 3XX-S-SB,
3XX-HF1-HF2, 3XX-HF1-HF3,
3XX-HF2-HF3, 3XX-L-5B,
3XX-HF1-HF2-HF3, 10-14 Cu 1 600 30 C 2(150),#
3XX-HS-SB, 3XX-LWW-SB,
672-GP-ST-XX, 672-GP-3/
4ST-XX, 672-GP-4000-XX,
672-GP-XX-NH,
672-GP-XX-KT55, 672-GP-XX-KT56,
672-GP-XX-KT57, 672-GP-XX-KT61,
672-GP-XX-KT62, 672-GP-XX-KT63,
672-GP-Y-XX, 672-GP-XX-KT55-KT56,
672-GP-XX-KT55-KT57,
672-GP-XX-KT56-KT57,
672-GP-XX-KT55-KT56-KT57,
672-GP-XX-KT61-KT62,
672-GP-XX-KT61-KT63,
672-GP-XX-KT62-KT63,
672-GP-XX-KT61-KT62-KT63
3XX-SPSE, 3XX-SP 12-22Str Cu 2 30 600 20 C 2(150),#
140X301 *, ++ Al-Cu 2 + 600 255 C 2(150)
140X303 *, ++ Al-Cu 2 + 600 310 C 2(150)
140X306 *, ++ Al-Cu 2 + 600 255 C 2(150)
140X401 *, ++ Al-Cu 2 + 600 125
150
C 2(150), 6 (16 x 12 x 6),##
140X402 *, ++ Al-Cu 2 + 600 175 C 2(150), 6 (16 x 12 x 6),##
140X403 *, ++ Al-Cu 2 + 600 150 Cu C 2(150)
125 Al
140X404 *, ++ Al-Cu 2 + 600 310 C 2(150), 6 (16 x 12 x 6),##
140X405 *, ++ Al-Cu 2 + 250 175 A 2(150)
140X410 *, ++ Al-Cu 2 + 600 310 Cu C 2(150)
250 Al
140X411 *, ++ Cu 2 + 600 200 C 2(150)
140X417 *, ++ Cu 2 * 600 310 C 2(150)
140X801 *, ++ Al-Cu 2 + 600 255 C 2(150)
140X901 *, ++ Cu 2 + 600 175 C 2(150)
140X902 *, ++ Cu 2 + 600 175 C 2(150)

*See Report for wire range and torque values.

+-XX denotes number of terminal positions.

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded copper wire.

#Unique Conditions of Acceptability — The acceptability of the solder connectors, feed-through solder connectors and feed-through wire wrap connectors shall be determined in the end use application.

## Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered.


Cat. No.
Wire
Range
Wire
Type

FW
TQ
Lb In.

V
A
UG

CA
Cu Al
142X120 +, ++ Al-Cu 2 + 600 175 135 C 2(150)
142X121 +, ++ Cu 2 + 600 150 C 2(150)
142X301 +, ++ Al-Cu 2 + 300 175 C 2(150)
142X406 +, ++ Cu 2 + 600 200 C 2(150)
142X551 +, ++ Al-Cu 2 + 600 175 135 C 2(150)
142X552 +, ++ Al-Cu 2 + 600 115 90 C 2(150), 6 (16 x 12 x 6)
142X560 +, ++ Al-Cu 2 + 300 175 135 C 2(150)
142X568 +, ++ Al-Cu 2 + 300 175 135 C 2(150)
142X569 +, ++ Al-Cu 2 + 600 175 135 C 2(150)
142X570 +, ++ Al-Cu 2 + 600 175 135 C 2(150), 6 (16 x 12 x 6),#
142X572 +, ++ Al-Cu 2 + 600 175 135 C 2(150), 6 (16 x 12 x 6)
142X575 +, ++ Cu 2 + 600 150 C 2(150)
142X579 +, ++ Al-Cu 2 + 600 150 C 2(150)
142X970 +, ++ Cu 2 + 600 175 C 2(150), 6 (16 x 12 x 6),#
1453401 +, ++ Al-Cu 2 + 600 2280 1860 C 2(150)

+See Report for wire range and torque values.

++ These terminal blocks are acceptable for use with Class G, H, I, K and DLO flexible stranded copper wires.

# Unique Conditions of Acceptability - i.e., This terminal block is intended for use with miscellaneous fuses. These fuses are not intended for branch-circuit overcurrent protection. Markings concerning fuse replacement and location should be considered.


Cat. No.
Wire
Range
Wire
Type

FW
TQ
In.-Lb

V

A

UG

CA
1103P, -04P, 4-6 Al 2 45 600 70 C 2(150)
-06P 8 Al 40
4-6 Cu 25-45
8 Cu 25-40
10-14 Cu 25-35
1102, -02-PS, 18-6 Cu 2 30 600 65 C 2(150)
-04, -04-PS, 12-6 Al
-06, -06-PS,
-07, -07-PS,
-08, -08-PS,
-12, -12-PS
1202, -04, 4-6 Cu/Al 2 45 600 70 C 2(150)
-06 8 Cu/Al 40
10-12 Al 35
4-6 Cu 25-45
8 Cu 25-40
10-14 Cu 25-35
1102-S, -02-S-PS, 14-6 Cu 2 30 600 65 C 2(150), 4
-04-S, -04-S-PS,
-06-S, -06-S-PS,
-07-S, -07-S-PS,
-08-S, -08-S-PS,
-12-S, -12-S-PS
6H38TS++ 8-18 Sol Cu 2 16-20 600 50 C 2(150)*,4
10-16 Str, + Cu
6H716TS++ 8-18 Sol Cu 2 16-20 600 40 C 2(150)*,4
10-16 Str, + Cu
6H38TSKK++, 10-22 Str Cu 2 16-20 600 40 C 2(150)*,4
6H716TSKK++ 10-14 Sol Cu
6H12-TSCU-C++, 4-18 Cu 2 20 600 20 C 2(105)
-F++
6H12-TSAL-C++, 4-18 Cu 2 20 600 20 C 2(105)
-F++ 4-12 Al
6G38TS++ 8-18 Str, + Cu 2 16 600 50 C 2(130)*,4
10-16 Sol Cu
6G38TSKK++ 10-22 Str Cu 2 16 600 40 C 2(130)*,4
10-14 Sol Cu

All Cat. Nos. may include suffixes of up to nine alpha-numeric characters denoting non-electrical variations such as marking, packaging, customer identification or options.

+ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.

++-Catalog number may include combinations of suffixes and additional suffix numbers and letters.

*-These catalog numbers have wire ranges with multiple wire combinations. Please refer to the procedure report for exact wire combinations.

Cat.
No.+ ++
Wire
Range
Wire
Type

FW
TQ
In.-Lb

V

A

UG

CA
1XX-F1 thru -F6, 12-22 Cu 1 250 20 B 2(150),#
-F6, -HF1, -HF2,
-HF3, -HS, -JS, -L,
-LL, -LWW, -RJ,
-RJS, -S
670A-GP-3/4ST, 12-22 Cu 1 250 20 B 2(150),#
-GP-600J, -GP-600JS,
-GP-600RJXX,
-GP-600RJSXX-XX,
-GP-3000, -GP-ST,
-GP-Y, -GP-YSY
670A-GP-XX-KT19 12-22 Cu 1 250 20 B 2(150)
thru -GP-XX-KT27,
-GP-XX-KT119 thru
-GP-XX-KT127
670A-GP-XX-KT3865 12-22 Cu 1 150 20 B 2(150)
1XX-CRES, -P, 12-22 Cu 2 12 250 20 B 2(150),
-PS, -PSB, -SLB 12-22 Sol., Cu 2 9 250 20 B 3(6)
Str.
670A-GP-CRES, -GP-P, 12-22 Cu 2 12 250 20 B 2(150),
-GP-PS, -GP-PSB, 12-22 Sol., Cu 2 9 250 20 B 3(6)
-GP-XX-SLB Str.
1XX-SP 12-22 Cu 2 12 250 20 B 2(150)
12-22 Sol., Cu 2 9 250 20 B
Str.
670A-GP-XX-3865 12-22 Cu 2 12 250 20 B 2(150)
1XX-PSE, -PSI, 12-22 Cu 1 12 250 20 B 2(150),5
-SE, -SI 12-22 Sol., Cu 2, 9 250 20 B
Str. 1
670A-GP-PSE, -GP-PSI, 12-22 Cu 2 12 250 20 B 2(150),
-GP-SE, -GP-XX-SI 12-22 Sol., Cu 2 9 250 20 B 3(6)
Str.
2XXHB-HS, -JS, -L, 12-22 Cu 1 600 20 B,C 2(150),#
-LL, -LWW, -RJ,
-RJS, -S
2XXHB-F1 thru 12-22 Cu 1 600 30 B,C 2(150)
-F6, -HF1 thru
-HF3
2XXHB-CRES, -P, 12-20Sol Cu 2 9-20 600 20 B,C 2(150),
-PS, -PSB, -SLB 12-22Str 3(6)
2XXHB-SP, -SPSE 12-22Str Cu 2 9-20 600 20 B,C 2(150)
2XXHB-PSE, -PSI, 12-22 Cu 1 600 20 B,C 2(150),5
-SE, -SI
2XX-HS, -JS, -L, 12-22 Cu 1 250 20 B 2(150)
-LL, -LWW, -RJ,
-RJS, -S
2XX-F1 thru -F6, 12-22 Cu 1 250 30 B 2(150)
-HF1 thru -HF3
671-GP-3/4ST, 12-22 Cu 1 250 20 B 2(150)
-GP-601J, -GP-601JS,
-GP-601RJXX,
-GP-601RJSXX-XX,
-GP-4000, -GP-ST,
-GP-Y, -GP-YSY
671-GP-XX-KT37 12-22 Cu 1 250 30 B 2(150)
thru -GP-XX-KT45
2XX-CRES, -P, 12-20Sol Cu 2 9-20 250 20 B 2(150),
-PS, -PSB, -SLB 12-22Str 3(6)
671-GP-XX-CRES, 12-20Sol Cu 2 9-20 250 20 B 2(150),
-GP-XX-P, -GP-XX-PS, 12-22-St 3(6)
-GP-XX-PSB, -GP-XX-SLB
2XX-SP, -SPSE 12-22Str Cu 2 9-20 250 20 B 2(150)
671-GP-XX-3760, 12-22Str Cu 2 9-20 250 20 B 2(150)
-GP-XX-3765,
-GP-XX-3767
2XX-PSE, -PSI, 12-22 Cu 1 250 20 B 2(150),5
-SE, -SI
671-GP-XX-PSE, 12-22 Cu 1 250 20 B 2(150),5
-GP-XX-PSI,
-GP-XX-SE,
-GP-XX-SI
621RZ-HS, -JS, -L, 12-22 Cu 1 600 20 B,C 2(150),#
-LL, -LWW, -RJ,
-RJS, -S
621RZ-F1 thru -F6, 12-22 Cu 1 600 30 B,C 2(150)
-HF1 thru -HF3
621RZ-CRES, -P, 12-20Sol Cu 2 9-20 600 20 B,C 2(150),
-PS, -PSB, -SLB 12-22Str 3(6)
621RZ-SP, -SPSE 12-22Str Cu 2 9-20 600 20 B,C 2(150)
621RZ-PSE, -PSI, 12-22 Cu 1 600 20 B,C 2(150),5
-SE, -SI
671RZ-HS, -JS, -L, 12-22 Cu 1 250 20 B 2(150)
-LL, -LWW, -RJ,
-RJS, -S
671RZ-F1 thru -F6, 12-22 Cu 1 250 30 B 2(150)
-HF1 thru -HF3
671RZ-CRES, -P, 12-20Sol Cu 2 9-20 250 20 B 2(150),
-PS, -PSB, -SLB 12-22Str 3(6)
671RZ-SP, -SPSE 12-22Str Cu 2 9-20 250 20 B 2(150)
671RZ-PSE, -PSI, 12-22 Cu 1 250 20 B 2(150),5
-SE, -SI
4XX-HS, -JS, -L, 10-22 Cu 1 600 30 C 2(150)
-LL, -LWW, -S
4XX-F1 thru -F6, 10-22 Cu 1 600 30 C 2(150)
-HF1 thru -HF3
4XX-CRES, -P, 10-22 Cu 2 20 600 30 C 2(150)##,
-PS, -PS, -SLB 3(10)
4XX-SP, -SPSE 10-22 Cu 2 30 600 20 C 2(150),4##
4XX-PSE, -PSI, 10-22 Cu 2 20 600 30 C 2(150),5##
-SE, -SI

+-XX denotes number of terminal positions.

++-Catalog number may include combinations of suffixes and additional suffix numbers and letters.

#-Unique Conditions of Acceptability — The acceptability of the solder connectors, feed through solder connectors and feed through wire wrap connectors shall be determined in the end use application.

##-When provided with crimp type connectors, terminal block is acceptable for 65 A when used with a Listed ring or fork torque rated for a size 6 AWG CU minimum.

Model
No.
Wire
Range
Wire
Type

FW
TQ
(In.-Lb)

V
A
Al Cu

UG

CA
8500020 * Cu 1/2 * 600 115 C 2(125), 5
8500022 * Cu 1 * 600 135 C 2(125), 5
2 115

*See Report for wire range and torque values

Terminal blocks, Types MAK2.5, MHK2, -3 with or without suffixes -BL or -C.


Type +
Wire
Range
Wire
Type

FW
TQ
Lb In.

V

A

UG

CA
MIK3 12-22 Cu 2 5 600 20 B/C 2(105),4###
MIK4, -5, 10-22 Cu 2 13.3 600 30 B/C 2(105),4###
MIKH4
MIK10 8-22 Cu 2 13.3 600 50 B/C 2(105),4###
MIK16, MFK16 6-22 Cu 2 18 600 65 B/C 2(105),4###
MIK25 4-8 Str Cu 2 53 600 85 B/C 2(105),4###
MIK70 4/0-4 Cu 1 50 Slot 600 250 B/C 2(105),###
75 Hex
MIK120 310 Cu 2 360 600 200 C 2(105),5
MIK240 300 Cu 2 480 600 285 C 2(105),5
MIKE4 10-22 Cu 2 8 2(105),4,
###, ####
MIKE10 8 Str Cu 2 13.3 2(105),4,
###, ####
MIKE16 6 Str Cu 2 18 2(105),4,
###, ####
8500018 4-10 Cu/Al 1 load 22-50 (1)
22 (2)
600 65 D,C 2(125), ++
2 line
8500057 6-12 Cu 1/2 22 300 65 B,C 2(125)
4-8 Al

All Cat. Nos. may include suffixes of up to nine alpha-numeric characters denoting non-electrical variations such as marking, packaging, customer identification or options.

Note: Above types may be followed by -BL or C.

Note 1: For unprepared conductors using external hex drive on screw.

Note 2: For unprepared or prepared conductors using Phillips drive on screw.

+-XX denotes number of terminal positions.

++ - Unique Conditions of Acceptability - Torque applies to the hex head securement means only.

###-Unique Conditions of Acceptability — The suitability of accessories such as connecting links, safety covers, grounding end clamp bracket and connecting clamps shall be determined in the end-use application.

####-These blocks are suitable for grounding applications only, and were not subjected to a Heating and Dielectric Withstand Test.

Terminal blocks Series ST722.

Cat.
No.
Wire
Range
Wire
Type

FW
TQ
kg cm

V

A

UG

CA
ST719 4-8 Str Cu 2 + 150 85 Dual B/C 2(125),5,#,##
ST722 2/0-8Str Cu 2 + 300 175 Dual, 115 Single B/C 2(125),5,###
Dual
115
Single
ST715 6-14 Str Cu 2 + 300 80 A B/C 2(125), 5,##
Dual
ST723 500-6 Str Cu 2 + 600 380 B/C 2(125), 5, #, ##
Dual
175
Single

All Cat. Nos. may include suffixes of up to nine alpha-numeric characters denoting non-electrical variations such as marking, packaging, customer identification or options.

+ - See report for torque ratings.

Unique conditions of Acceptability.

# - When terminal blocks are used with Listed lugs having one mounting hole for securement the single stud ampacity rating is used. When Listed lugs having two mounting holes for securement the dual stud ampacity rating is used.

## - When provided with covers, the suitability of the covers shall be judged in the end-use application. The covers may be constructed from various plastic and the suitability of the plastic shall be investigated per the latest requirements of UL 746C if the cover is used in lieu of spacings.

Wire
Range, AWG/kcmil

A

Cat.
No.


Line


Load
Wire
Type,
Al/Cu


FW

TQ
in-lbs


V


Al


Cu


UG


CA
EPBAD41, EPBAP41, EPBCD41, EPBCP41 may be followed by 1, 2, 3 or 4, may be followed by up to five characters for manufacturing designation 3/0-14 Str, 10-14 Sol, ++ 3/0-14 Str 10-14 Sol (2) No. 4 Str (2) No. 6 Str (2) No. 8 Str (2) No. 10 Str (2) No. 12 Str (2) No. 14 Str Cu 2 + 600 150 195 B, C 2(125), 6 (16 x 12 x 6)
3/0-6 3/0-6 Al
EPBAD44, EPBAP44, EPBCD44, EPBCP44 may be followed by 1, 2, 3 or 4, may be followed by up to five characters for manufacturing designation 3/0-14 Str 10-14 Sol, ++ 2-14 Str 10-14 Sol (2) No. 6 Str (2) No. 8 Str (2-4) No. 10 Str (2-4) No. 12 Str (2-4) No. 14 Str Cu 2 + 600 150 195 B, C 2(125), 6 (16 x 12 x 6)
3/0-6 Str 3/0-6 Str Al
EPBAD71, EPBAP71, EPBCD71, EPBCP71 may be followed by 1, 2, 3 or 4, may be followed by up to five characters for manufacturing designation 250-6, ++ 250-6 Cu 2 + 600 460 580 B, C 2(125)
250-6 250-6 Al 2 + 600 460 580 B,C 2(125)
EPBAD74, EPBAP74, EPBCD74, EPBCP74 may be followed by 1, 2, 3 or 4, may be followed by up to five characters for manufacturing designation 400-6 Str3/0-14 Str10-14 Sol, ++ 2-14 Str10-14 Sol (2) No. 6 Str (2) No. 8 Str (2-4) No. 10 Str (2-4) No. 12 Str (2-4) No. 14 Str Cu 2 + 600 305 380 B, C 2(125)
400-6 Str3/0-6 Str 2-6 Str Al

All Cat. Nos. may include suffixes of up to nine alpha-numeric characters denoting non-electrical variations such as marking, packaging, customer identification or options.

+ - See Report for Torque ratings.

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.





Cat. No.


Suitable
Conductors
kcmil/AWG


Overcurrent Protection
Fuse Required
Class/Max Amp Rating


SCCR,
RMS
Sym A



Volts
Max
  Line Load J T RK1 RK5 G CC    
141X204 2-6 Cu 4-10 Cu 150 150 100 -30 60 30 100,000 600
141X400++ 2-6 Cu 10-14 Cu 200 200 200 100 60 30 200,000 600
8-10 Cu 10-14 Cu 100 100 100 30 60 30 100,000 600
142X552 2-6 Cu 2-6 Cu 300 300 200 100 60 30 100,000 600
8-10 Cu 8-10 Cu 150 150 100 -30 60 30 100,000 600
142X570 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
140X401 2/0-6 Cu 4-14 Cu 200 200 200 100 30 200,000 600
60 100,000 600
140X404 350-3/0 Cu 4-8 Cu 400 400 400 200 30 200,000 600
600 60 100,000 600
2/0-6 Cu 4-14 Cu 200 200 200 100 30 200,000 600
60 100,000 600
143X553 400-3/0 Cu 2-8 Cu 400 400 400 200 30 200,000 600
600 60 100,000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 30 200,000 600
60 100,000 600
143X123 250-6 250-6 300 300 200 100 60 30 100,000 600
143X124 250-6 250-6 300 300 200 100 60 30 100,000 600
143X126 350-1/0 350-1/0 400 400 400 100 60 30 100,000 600
350-6 350-6 300 300 200 100 60 30 100,000 600
144X560 400-3/0 Cu 2-8 Cu 400 400 400 200 60 30 100,000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
145X552 500-3/0 Cu 2-8 Cu 400 400 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
143X953 500-3/0 Cu 2-8 Cu 400 400 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
132X572 2/0-6 Cu 2/0-6 Cu 200 200 200 100 60 30 100,000 600
142X970 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
132X970 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
132X570 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
132X580 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
143X955 2/0-2 Cu 4-8 Cu 400 400 400 100 60 30 100,000 600
4-6 Cu 10-14 Cu 200 200 200 100 60 30 100,000 600
133X555 2/0-2 Cu 4-8 Cu 400 400 400 100 60 30 100,000 600
4-6 Cu 10-14 Cu 200 200 200 100 60 30 100,000 600
132X574 2/0-6 Cu 2/0-6 Cu 300 300 200 100 60 30 100,000 600
8-10 Cu 8-10 Cu 150 150 100 30 60 30 100,000 600
133X955 2/0-2 Cu 4-8 Cu 400 400 400 100 60 30 100,000 600
132X972 2/0-6 Cu 2/0-6 Cu 300 300 200 100 60 30 100,000 600
4-6 Cu 10-14 Cu 200 200 200 100 60 30 100,000 600
143X552 400-3/0 Cu 2-8 Cu 400 400 400 100 60 30 100,000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
133X552 400-3/0 Cu 2-8 Cu 400 400 400 100 60 30 100,000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
141X300 2-6 Cu 2-6 Cu 200 200 200 100 60 30 100,000 600
8-10 Cu 8-10 Cu 100 100 100 - 60 30 100,000 600
145X579 500-3/0 Cu 2/0-6 Cu 400 400 400 100 60 30 100,000 600
2/0-4 Cu 8-14 Cu 200 200 200 100 60 30 100,000 600
140X402 2/0-6 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
133X595 600-3/0 Cu 4-8 Cu 600 600 400 200 60 30 100,000 600
2/0-2 Cu 4-14 Cu 200 200 200 100 60 30 100,000 600
143X587 500-3/0 Cu 350-6 Cu 600 600 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
133X587 500-3/0 Cu 350-6 Cu 600 600 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
133X588 600-3/0 Cu 1/0-8 Cu 600 600 400 200 60 30 100,000 600
2/0-2 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
133X554 350-3/0 Cu 2/0-1 Cu 600 600 400 200 60 30 100,000 600
2/0-6 Cu 4-10 Cu 200 200 200 100 60 30 100,000 600
145X594 500-3/0 Cu 2-8 Cu 600 600 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
144X551 500-3/0 Cu 2-8 Cu 600 600 400 200 60 30 100,000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100,000 600
133X320 2)250-1/0 Cu 2)250-1/0 Cu 600 600 400 200 60 30 100,000 600
133X559 350-4 Cu 350-4 Cu 400 400 400 100 60 30 65,000 600
133X596 250-1/0 Cu 4-14 Cu 600 600 600 200 60 30 100000 600
133X597 250-1/0 Cu 2-14 Cu 600 600 600 200 60 30 100000 600
133X585 600-3/0 Cu 2-8 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
2/0-2 Cu 2-14 Cu 200 200 200 100 60 30 100000 600
133X953 500-3/0 Cu 2-10 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
2/0-4 Cu 2-14 Cu 200 200 200 100 60 30 100000 600
142X572, 142X120 2/0-6 Cu 2/0-6 Cu 300 300 200 100 60 30 65,000 600
143X554 350-3/0 Cu 2/0-3 Cu 450 450 400 200 60 30 100,000 600
2/0-6 Cu 4-6 Cu 300 300 200 100 60 30 100,000 600
143X555 2)2/0-2 Cu 4-8 Cu 400 400 400 100 60 30 100,000 600
2)4-6 Cu 10-14 Cu 300 300 200 100 60 30 100,000 600
143X559 350-4 Cu 350-4 Cu 400 400 400 100 60 30 65,000 600
145X129 2)350-4 Cu 2)350-4 Cu 450 450 400 -200 -60 -30 100,000 600
2)350-4 Cu 2)350-4 Cu 600 600 400 200 60 30 50,000 600
145X301 2)500-4 Cu 2)500-4 Cu 600 600 400 200 60 30 100,000 600
145X586 500-250 Cu 2/0-4 Cu 600 600 400 200 60 30 100000 600
4/0-4 Cu 2/0-10 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
145X599 2)500-4/0 Cu 2)500-4/0 Cu 600 600 400 200 60 30 65,000 600
2)3/0-4 Cu 2)3/0-4 Cu 400 400 400 100 60 30 65,000 600
145X986 500-250 Cu 2/0-4 Cu 600 600 400 200 60 30 100000 600
4/0-4 Cu 2/0-6 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
145X592 500-250 Cu 4-8 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
4/0-4 Cu 4-14 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
145X992 500-250 Cu 2-8 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
4/0-4 Cu 2-14 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
142X574, 142X553 2/0-6 Cu 2/0-6 Cu 200 200 200 100 60 30 100000 600
8-10 Cu 8-10 Cu 100 100 100 100 60 30 100000 600
133X360 600-2 Cu 600-2 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
144X557 600-2 Cu 600-2 Cu 600 600 50000 600
400 400 400 200 60 30 100000 600
EPB CD44X,EPB CP44X 2/0-6 Cu 2-14 Cu 300 300 200 100 60 30 100,000 600
EPB AD44X,EPB AP44X 2/0-6 Cu 2-14 Cu 300 300 200 100 60 30 100,000 600
EPB CD41X,EPB CP41X 2/0-6 Cu 2/0-6 Cu 300 300 200 100 60 30 100,000 600
EPB AD41X, EPB AP41X 2/0-6 Cu 2/0-6 Cu 300 300 200 100 60 30 100,000 600
EPB AP74 may be followed by 1, 2, 3, 4 400-3/0 Cu 2-8 Cu 400 400 400 200 60 30 100000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 60 30 100000 600
EPB CP74 may be followed by 1, 2, 3, 4 400-3/0 Cu 2-8 Cu 400 400 400 200 60 30 100000 600
2/0-6 Cu 2-14 Cu 200 200 200 100 60 30 100000 600
EPB AP71 may be followed by 1, 2, 3, 4 250-1/0 Cu 250-1/0 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
2-6 Cu 2-6 Cu 400 400 400 200 60 30 100000 600
EPB CP71 may be followed by 1, 2, 3, 4 250-1/0 Cu 250-1/0 Cu 600 600 600 50000 600
400 400 400 200 60 30 100000 600
2-6 Cu 2-6 Cu 400 400 400 200 60 30 100000 600

++ - These terminal blocks are acceptable for use with Class G, H, I, K, and DLO flexible stranded wire.




Cat. No.

Suitable
Conductors
kcmil/AWG


Overcurrent Protection
Circuit Breaker Required

SCCR,
RMS
Sym A


Volts
Max
  Line Load Mfr Type Max Amp    
142X570 2/0 - 1 4 - 10 Allen Bradley 140U-J3D3
140U-J6D3
250 22000 480
2 - 4 4 - 12 Allen Bradley 140U-J3D3
140U-J6D3
250 22000 480
2 - 6 4 - 14 Allen Bradley 140U-H3C3 125 30000 480
6 14 Allen Bradley 140U-H6C3 125 50000 480
141X400 2 - 10 10 - 14 Allen Bradley 140U-H3C3
140U-H6C3
125 25000 480
143X553 400 - 3/0 2 - 8 Allen Bradley 140U-K6X3
140U-K3X3
400 65000 480
4/0 - 4 2 - 12 Allen Bradley 140U-J6X3
140U-J3X3
250 25000 480
143X953 2/0 - 4 2 - 8 Square D JDL36250 250 18000 480
Square D JGL36250 250 35000 480
Square D JJL36250 250 65000 480
Square D JLL36250 250 65000 480



Cat. No.

Suitable
Conductors
kcmil/AWG


Overcurrent Protection
Circuit Breaker Required

SCCR,
RMS
Sym A


Volts
Max
  Line Load Mfr Type Max Amp    
141X300 1) 2 - 6 1) 2 - 6 Square D JDL36250 250 18 kA 480
Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
141X300 1) 8 - 10 1) 8 - 10 Square D HDL36100 100 18 kA 480
Square D HGL36100 100 35 kA 480
Square D HJL36100 100 65 kA 480
Square D HLL36100 100 65 kA 480
141X400 1) 2 - 6 4) 10 Square D JDL36250 250 18 kA 480
Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
141X400 1) 8 - 10 4) 14 Square D JDL36250 250 18 kA 480
Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D HDL36100 100 18 kA 480
Square D HGL36100 100 35 kA 480
Square D HJL36100 100 65 kA 480
Square D HLL36100 100 65 kA 480
140X401 1) 2/0 - 6 6) 4 - 10 Square D JDL36250 250 18 kA 480
Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
145X579 1) 2/0 - 4 6) 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
145X552 1) 2/0 - 4 12) 2 - 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
1) 350 - 4 12) 2 - 10 Allen Bradley 140U-J3D3 250 35 kA 480
1) 500 - 4 12) 2 - 6 Allen Bradley 140U-K3D3 400 35 kA 480
144X560 1) 2/0 - 6 6) 2 - 10 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
143X552 1) 2/0 - 4 4) 2 - 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
143X555 2) 1/0 - 8 6) 4 - 10 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
2) 2/0 - 2 6) 4 - 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
143X955 Square D JLL36250 250 65 kA 480
Square D JDL36175 175 18 kA 480
2) 4 - 6 6) 10 - 12 Square D JGL36175 175 35 kA 480
Square D JJL36175 175 65 kA 480
Square D JLL36175 175 65 kA 480
Square D JDL36250 250 18 kA 480
143X553 1) 2/0 - 6 6) 2 - 10 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
142X570 1) 2/0 - 10 4) 4 - 10 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
142X121 1) 1/0 - 8 1) 1/0 - 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
Square D JDL36250 250 18 kA 480
142X970 1) 2/0 - 8 4) 4 - 8 Square D JGL36250 250 35 kA 480
Square D JJL36250 250 65 kA 480
Square D JLL36250 250 65 kA 480
140X404 350 - 6 4 - 12 GE SFPA36AT0250 250 100kA 480

Note: X Denotes number of poles

Note: n) Denotes number of termination points


Marking: Company name or trademark, oval with or without the word "Marathon" across it or "M" in a circle in a rectangle or and part and catalog designation on carton instead of on the devices.
Last Updated on 2009-12-21

Questions?

Notice of Disclaimer

Page Top

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2010 Underwriters Laboratories Inc.®"