JDDZ.E2137
Cartridge Fuses, Nonrenewable

Page Bottom


Cartridge Fuses, Nonrenewable


See General Information for Cartridge Fuses, Nonrenewable

FERRAZ SHAWMUT INCE2137
374 MERRIMAC ST
NEWBURYPORT, MA 01950 USA


Fuses with marked interrupting capacity ratings:


Class
Interrupting Capacity
Cat. No.+
Fuse Rating
V ac RMS Symmetrical Amps V ac Amps
CC 600 200,000 ATM-R@@@ 600 0-30
CC 600 200,000 ATMR30-HD 600 30
CC 600 200,000 ATDR## 600 0-30
CC 600 200,000 ATQR 600 1/4-30
G 600 100,000 AG 600 0-20
G 480 100,000 AG 600 21-60
J 600 200,000 A4J|Lo, AJT##-A, HSJ-a|Lo 600 0-600
K5 250 50,000 OT* 250 0-600
K5 250 50,000 25000-25200 250 0-100
K5 600 50,000 OTS 600 0-600
L 600 200,000 A4BT+++, 600 601-6000
A4BQ+++, *A, **
L 600 200,000 A4BY++ 600 601-6000
RK1 250 200,000 A2K#, #* 250 0-600
RK1 600 200,000 A6K# 600 0-600
RK1 250 200,000 A2D#, @@@@ 250 0.1-600
RK1 600 200,000 A6D#,#** 600 0.1-600
RK1 250 200,000 WN# 250 200, 400 or 600
RK1 600 200,000 WS# 600 200, 400 or 600
RK1 600 200,000 HSRK 600 61-600
RK5 250 200,000 FT#, TR#*b 250 0-600
RK5 600 200,000 FTS#++++, 600 0-600
TRS#*b
RK5 600 200,000 TRS-DC# 600 61-600
RK5 250 200,000 TR+#*b 250 0-600
RK5 600 200,000 TRS+#*b 600 0-600
RK5 250 200,000 TRNR 250 0-400
RK5 600 200,000 TRSR 600 0-400
T 300 200,000 A3T+@ 300 0-1200
T 600 200,000 A6T+@@ 600 0-800

@ Also rated 160 volts DC, interrupting rating 50KA at 160 VR.

@@ Also rated 300 volts DC, interrupting rating 100KA at 300 VDC.

@@@ Also rated 600 volts DC, interrupting rating 100 kA at 600 VDC.

@@@@ Also rated 250 volts DC, interrupting rating 100 kA at 250 VDC.

* Fuses rated 101-200 amps may have suffix letter H.

# With suffix letter R.(The TRS DC Types 61-600A, rated 600 vdc, 100KA interrupting rating).

## -1 Time delay type (The AJT fuses are rated 600 vac/500 vdc; The DC int. rating is 100KA).

### May or may not be followed by suffix for manufacturer's internal use.

#* Types A2K up to 60 amps also rated 250 v. DC; 10kA DC interrupting rating.

#**Types A6D up to 600 amps also 600v. DC, 100 kA DC interrupting rating.

+ Designation indicated followed by amp rating numeral.

++ May or may not be followed by Type 55 and/or suffix TI.

+++ May or may not be followed by suffix "TI" .

++++ Types FTS 0-100 amps also rated 600 vdc, 20kA DC interrupting rating.

*A These fuses rated 500 vdc, 100KA dc interrupting capacity.

a - The HSJ Types are rated 0 to 6 00 Amperes.

|Lo - The A4J and HSJ fuses rated 0-30 A have a 300 Vdc, 100 kA interrupting rating.

*b - May or may not be followed by the suffix "ID".

** - May or may not be followed by suffix "-TA".

Note: Only those fuses bearing the Listing Mark of Underwriters Laboratories Inc. and having the specified interrupting capacity rating included as part of the marking on the fuse itself are considered to comply with interrupting capacity requirements.

Last Updated on 2009-09-21

Questions?

Notice of Disclaimer

Page Top

The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.

UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2009 Underwriters Laboratories Inc.®"