APAW.BP511 Police Station Alarm Units |
Police Station-connected Alarm Units
Type AB, AB-12 bell housing.
Model Mini-Modularm. Police station connect receiving unit.
Models 4208U, 4208SN, Control unit Accessory: Eight-Zone remote point modules, to be employed with manufacture's compatible Listed Control Unit Systems as indicated in the installation instructions.
Control unit accessory: Two-Zone expander module, Model 4190U, suitable for use with manufacturer's compatible Listed Control Units as indicated in the installation instructions.
Control unit accessories, Model 4101SN-XX Multiplex single zone expander and relay module, suitable for use with the manufacturer's compatible Listed control units as indicated in the installation instructions.
Model 1022-12. Multiple zone Grade A police station connect control units with polarity reversing police station connect relay for basic line security.
Some of the above products are found in file S789.
Model 678UL-B digital alarm communicator transmitter interface panel for use with Listed premises control unit suitable for basic line security. (Grade A).
Model CAPS computerized alarm processing unit for use with Model 685 digital alarm receiver, Model DP9001 printer and Model D200 CRT.
Model Vista-50 PUL, Vista-50, UL4140XMPT-UL control units, suitable for Grade A police station connected burglar alarm system when programmed for 24 hour test reporting or a Listed two-way Longe Range radio. suitable for Grade AA (Hight Line Security)
when used in conjunction with Model 7920SE LORRA.
Models Vista-50 PUL, Vista-50, UL4140XMPT-UL control units, suitable for Grade A police station connected burglar alarm system when programmed for 24 hour test reporting or can be used with Model 346 polarity reversing relay/voltage booster or Model 7720 LORRA. Suitable for Grade AA (High Line Security) when used in conjunction with Model 445 direct wire transmitter or Model 7920SE LORRA.
Combination control unit systems, Models 4153GS and 4153LS consisting of the 4153ML main board, 4190 remote point module, 4208HM remote point module, 4208HM-1 remote point module power supply, 4157 console and Sentral Model 5402 shock sensor for mercantile safe and vault systems. Suitable for Grade A service when used with a Listed Burglar Alarm Sounding Device in a Listing Housing and with Listed Grade A Bell Housing. Provided with integral digital transmitter for connection to Listed digital communicator receiver at the central station to provide basic line security.
Control unit accessories: 4208HM remote point module and 4208HM-1 remote point module power supply intended for use with the Models 4153GS and 4153LS controls.
Combination control units, Models Vista-10SE, V10SMITH, consisting of Model SAVS10SECE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model Vista-10SEADT consisting of Models 10ADTE, 10ADTED or 10ADTEG, Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model SAFEWATCH PRO & SECURITY MANAGER consisting of Model SA10ADTEG or SA10ADTE2 Sub-Assembly Circuit Board and Model COM-ULCommercial Control Unit Enclosure ; Model Vista-10ROSE consisting of Model SAVS10SECE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model V-10SE/WT consisting of Model SAVS10SECE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure;
Model Vista-10P1PACK consisting of Model SAVS10SECE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model Vista-10PASE consisting of Model SAVS10SECE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Models V10SELECT, V12C consisting of Model SAF145 Sub-Assembly Circuit Board and Model RES-UL Household Enclosure.
Model Vista-40 consisting of Model SA4142-4AD Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model Vista-50P, Vista-50PADT consisting of Model SA4142-2AD4 Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure;
Models Vista-50PEN, Vista-50PENADT, Vista-128B, Vista-128BP consisting of Model SAVIS128B Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure; Model Vista-250BP consisting of Model SA4142-22 Sub-Assembly Circuit Board and Model COM-UL Household Enclosure; Model Vista-20SE consisting of Model SAVS20SEE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, Model Vista-20HWSE consisting of Model SAVS20HWSEE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, Model Vista-20AMT3 consisting of Model 20AMTE Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, Model Vista-20BAY consisting of Model SAV20BAY sub-assembly circuit board and Model COM-UL Commercial Control Unit Enclosure. Enclosure intended for use with the other separately Listed accessories as indicated in the manufacturer's installation instructions. Model 250-P1 consisting of model 250-P1 sub-assembly circuit board and model COM-UL Commercial Control Unit Enclosure, intended for use with other separately Listed accessories as indicated in the manufacture's installation instructions, Combination control unit, Model Vista-15 consisting of Model SAVS15SEC Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, intended for use with other separately Listed accessories as indicated in the manufacturer's Installation Instructions. Combination control unit, FA-148C consisting of Model SAFA148C Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, intended for use with other seperately Listed accessories as indicted in the manufacturer's Installation Instructions. Model AM100 consisting of Model 20AMTE Sub-Assembly Circuit Board of Model COM-UL Commercial Control Unit Enclosure. Combination control units, Model SL150 consisting or Model SAAM150 Sub-Assembly Circuit Board and Model RES-UL Household Enclosure; Model SAFEWATCH PRO 2000 &
SECURITY MANAGER 2000 consisting of Model SAVS20ADT-1 or SAVS20ADT Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure. Intended for use with other separately Listed accessories as indicated in the manufacturer's installation instructions. Intended for use with other separately Listed accessories as indicated in the manufacturer's installation instructions. Above control units provided with integral digital alarm communicator.
Control unit accessory, Model 4146 Keyswitch suitable for use with Listed control panels as indicated in the specific control panel installation instructions. When used in commercial burglar alarm installations, the Keyswitch must be mounted within the protected premises.
Alarm system, Model 7600. Refer to AMCX card of BP1143 for description. Provides basic line security and Grade A police-connect service when connected as described for Grades A, B or C central station service and connected to Grade A police-connect control unit.
Control unit accessories, Model 5140DLM back up dialer, Model 140LED indicator module.
Control unit accessories, Models FA210KP, 6128 remote console, Models 6137, 6137R to be employed with manufactures compatible Listed control unit systems as indicated in the installation instructions.
Control unit accessories, Models COM-UL Commercial Control Unit enclosures. Suitable for use with this manufacturer's separately Listed Sub-Assembly Circuit Boards to form a Listed commercial burglar or fire alarm system control unit.
Combination control unit system, Model FA1000UL intended for use with the following accessories: Model WA112-1 tamper switch, 4152LMB polling loop adapter, 4144-2 terminal block, 1360 power pack, with one or more of the following consoles: FA300KP, FA500KP, 5137, with or without the 4139, 4191WH, 4194, 4197, 4208 remote point accessories. Suitable for Grade A service when used with this manufacturer's Model AB bell housing and AD10-12 bell. Suitable for basic line security with the 4171ATX-XM, 4171XT-XM dialers.
Suitable for Grade A service (basic line security) when used with the manufacturer's separately Listed Models 688 switching module, 687 voltage regulator, Listed compatible Grade A standing device and 4171ATX-XM or -TX-XM subassemblies. Suitable for Grade AA service (high line security) when used with the manufacturer's separately Listed Model 688 switching module, 687 voltage regulator.
Serial number interface module (SIM), Model 4193SN a UL Listed junction box for the application must be employed, or the device can be mounted inside the protective device. Must be mounted within 3 feet of the initiating device with no intervening barriers when using the Unsupervised Zone.
Serial number interface module (SIM), Model 4293SN. Suitable for use with Listed control panels as indicated in the specific control panel installation instructions and installed as follows:
The 4293SN must be mounted inside the enclosure of the device it is connected to with wire length from the 4293SN to the terminals to the normally closed device less than 3 feet.
Central station RF transceivers kit, Model 7810RT, consisting of: one Model 7830R RF Transceiver, one Model 685-5N Line Card, DB25 Interconnecting Cable Assembly. Two 7810RT units must be installed at the C/S. These units must be used with a Listed Ademco Model 685 DACR .
Premises RF transceiver, Model 7860R, suitable for central station grade A, AA, BB, C or CC service when installed in accordance with installation instructions. A listed digital alarm transmitter must be used in conjunction with this system.
Model 4297 Polling Loop Extender Module (S789).
Control unit accessory, Model 472415DVAC communication module, for use with Listed 472407 (Focus 75) system. Suitable for Grade AA line security when used with the Listed ADT receiver, Model Centra Scan 600/6000.
Control unit accessories, Model 4219 Wired Zone Expander and Models 4229 and 42291 Wired Zone Expander/Relay modules. Suitable for use with Listed control panels as indicated in the specific control panel installation instructions. Units must be mounted inside the protected area.
Combination control unit system, Model 5120XM for use with Model 1451 transformer. Suitable for Grade A Police Station Connected Burglar Alarm System Service when used with a UL Listed Burglar Alarm Sounding Device/Housing and (A) programmed to transmit 24 hour test report signals, or (B) used with 7720 LORRA, or (C) used with 7620 ULF LORRA. Suitable for Grade AA Police Station Connected Burglar Alarm System service when used with a UL Listed Burglar Alarm Sounding Device/Housing and Model 7920SE LORRA. Suitable for Safe or Vault Police Station Connected Burglar Alarm System service under the above Graded when also used with a UL Listed shock sensor, and rear tamper on the control panel enclosure.
Model 472462 (FOCUS 200 PLUS) control unit, consisting of Model SAFOC200 sub-assembly circuit board and Model COM-UL enclosure. Suitable for Grade A when configured for used with the integral DACT and a Listed local alarm sounding device and alarm housing as indicated in the installation instructions. Suitable for Grade AA when configured 472491 AC Communicator (multiplex). When mounted outside the protected area a Listed shock sensor must be installed inside the control unit and a rear pry-off tamper on the back of the control unit enclosure. May include accessories Models 472270 Access Control Interface, 148320 Junction Box, 47240A Backup DACT, 427368 SIM Gateway, 248239 PID Gateway, 471715 Printer Interface, 471877 QUADPID, 471883 COPID and 472388 SIM (Sensor Interface Module).
Control unit sub-assembly, Model 472491 AC Communicator Module. Must be mounted inside the control unit. Suitable for use with Model 472462 (FOCUS 200 PLUS) control unit.
Control unit accessories, Models 61288B, 61378B, 6139B remote keypads to be employed with manufacturer's compatible Listed control unit systems as indicated in the installation instructions. May include a prefix or suffix number or letter(s).
Control unit accessories, Models 6148, 6148PL2, 6150, 6150A-BAY, 6150PL2, 6150PL3, 6160, 6150AAA, 6160A-BAY, 6160PL2, 6160PL3, 6160AAA, remote keypads to be employed with manufacturer's compatible Listed Control Unit Systems as indicated in the installation instructions.
Control unit accessory, Model 6160VADT, 6160V, 6150V, 6150V ADT, remote keypad to be employed with manufacturer's compatible Listed Control Unit Systems, as indicated in the installation instructions.
Control unit accessories , Model 6160CR, 6139, 6139R remote keypad to be employed with manufacturer's compatible Listed Control Unit Systems, as indicated in the installation instructions.
Control unit accessories, Model 7835C, 7835CF cellular control channel transceivers, suitable for Grade A, B or C Central Station Service when installed in accordance with the manufacturers installation instructions.
Control unit accessories, Models 6128B, 6137B, 6139 remote keypads to be employed with manufacturer's compatible Listed control unit systems as indicated in the installation instructions. May include a prefix or suffix number or letter(s).
Control unit accessories, Models FA215KP, FA260KP, FA560KP remote keypads to be employed with manufacturer's compatible Listed control unit systems as indicated in the Installation Instructions.
Combination control unit, Model Vista-15 consisting of Model SAVS15SEC or SAVS15SECS Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, intended for use with other separately Listed accessories as indicated in the manufacturer's Installation Instructions. Combination control unit, FA-148C consisting of Model SAFA148C Sub-Assembly Circuit Board and Model COM-UL Commercial Control Unit Enclosure, intended for use with other separately Listed accessories as indicated in the manufacturer's Installation Instructions.
Combination control units, Models Vista-15P, Vista-20P, FA148CP, FA168C, consisting of Model SAVS20P2 Sub-Assembly Circuit Board and Model COM-UL Enclosure or Unibank Enclosure, intended for use with other separately Listed accessories as indicated in the manufacturer's Installation Instructions.
Combination control units, Models Safewatch Pro 3000, Security Manager 3000 consisting of Model SAVS20P2 Sub-Assembly Circuit Board and Model COM-UL Enclosure or Unibank Enclosure, intended for use with other separately Listed accessories as indicated in the manufacturer's Installation Instructions.
Control unit accessories, Models FA250, FA550, FA6139. These designation represents cosmetic changes only, remote console, to be employed with manufactures compatible Listed control unit systems as indicated in the installation instructions. May include a prefix or suffix number or letter(s).
Control unit accessory, Model 4208SNF eight zone remote point module/Class A interface, to be employed with manufacture's compatible Listed Control Unit Systems as indicated in the Installation instructions.
Control unit accessory, Model 7820-XX long range, one way RF accessory slave transmitter. Where X may be any number from 0 to 9. Suitable for Central Station Grade A, B, C or Grade A Police Connect Service when installed in accordance with the manufacturer's installation instructions.
Control unit accessories, Models 7720, 7720V2, 7720PLUS-XX, 7720PLUS long range, one way RF accessory transmitter. Suitable for Grade A service when connected to a Listed control unit with digital alarm communicator transmitter and to a Model 659EN telephone line monitor as described in the installation instructions and programmed for "high security test
" (135S supervision interval). The control and transmitter shall be either located within the same room or interconnected in conduit. Suitable for grade B service when the protected premise control unit employs a Listed local bell; all wiring between the premise control unit and transmitter room must be rigit conduit (runs outside walls) or flexible conduit (inside walls or above ceiling). Suitable Grade B service when used with this manufacturer's Model AB Housing and AD10-12 Bell. Provided with integral digital transmitter for connection to Listed digital alarm communicator receiver.
Control unit accessories: Remote keypads, Models Symphony, iCenter, intended for use with manufacturer's Listed Compatible Control Units as specified in the Installation Instructions.
Control unit accessory: Modem, Model 8950T, intended for use with manufacturer's Listed Compatible Control Units, as specified in the Installation Instructions.
Control unit accessory: Messaging module, Model TeleSMART, intended for use with manufacturer's Listed Compatible Control Units as specified in the Installation Instructions.
Copyright © 2010 Underwriters Laboratories Inc.®
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Designs and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2010 Underwriters Laboratories Inc.®"