Online Certifications Directory

Fire Rated Assemblies (BXUV)

The summarized form of the test assembly is identified by an alphanumeric design number. The prefix letter designates the group of construction, the first number designates the type of protection and the other numbers and letters identify the particular assembly.

NUMBERING SYSTEM FOR FIRE RATED ASSEMBLIES

 

TYPES OF PROTECTION

 

Membrane Protection

Direct Applied Protection

Unprotected

Groups of Construction

000-099

100-199

200-299

300-399

400-499

500-599

600-699

700-899

900-999

Floors-Ceilings:
A or B* Concrete and Cellular Steel Floor
C - Glazing Systems

Concealed Grid Sys.

(Reserved)

Exposed Grid System

(Reserved)

Metal Lath

Gypsum Board

Misc.

SFRM+

Unprotected

D, E*, F* Concrete and Steel Floor Units

Concealed Grid Sys.

(Reserved)

Exposed Grid System

Mineral and Fiber Boards

Metal Lath

Gypsum Board

Mastic and Intumescent Coatings

SFRM+

Unprotected

G or H* Concrete and Steel Joists

Concealed Grid Sys.

(Reserved)

Exposed Grid System

Mineral and Fiber Boards

Metal Lath

Gypsum Board

Misc.

SFRM+

Unprotected

I
Non-load-bearing Horizontal Barrier

(Reserved)

(Reserved)

(Reserved)

(Reserved)

(Reserved)

Gypsum Board

(Reserved)

(Reserved)

(Reserved)

J or K
Concrete

Concealed Grid Sys.

(Reserved)

Exposed Grid System

Mineral and Fiber Boards

Metal Lath

Gypsum Board

Misc.

SFRM+

Unprotected

L or M
Wood Joist or Combination Wood and Steel Assemblies

Concealed Grid Sys.

(Reserved)

Exposed Grid System

(Reserved)

Metal Lath

Gypsum Board

Misc.

SFRM+

Unprotected

Beams:
N or O* for
Floor-Ceiling

Concealed Grid Sys.

(Reserved)

Exposed Grid System

Batts and Blankets or Mineral and Fire Boards

Metal Lath

Gypsum Board

Mastic and Intumescent Coatings

SFRM+

Unprotected

Roof-Ceiling:
P, Q* or R*

Concealed Grid Sys.

(Reserved)

Exposed Grid System

Mineral and Fiber Boards

Metal Lath

Gypsum Board

Misc.

SFRM+

Unprotected

Beams:
S or T* for
Roof-Ceiling

Building Units

(Reserved)

Exposed Grid System

Mineral and Fiber Boards

Metal Lath

Gypsum Board

Mastic and Intumescent Coatings

SFRM+

Unprotected

Wall and Partition:
U, V or W

Building or Partition Panels Units

(Reserved)

Insulating Concrete

Wood Stud, Gypsum Board, Lath &/or Plaster

Metal Stud, Gypsum Board, Lath &/or Plaster

Misc.

Metal Panels, Gypsum Board, Lath &/or Plaster

SFRM+

Masonry

Columns:
X, Y or Z*

Building Units

Prefabricated

Mat Materials

Batts and Blankets or Mineral and Fiber Boards

Metal Lath & Plaster

Gypsum Board

Mastic and Intumescent Coatings

SFRM+

Masonry

The prefix numbers with an asterisk (*) and the design numbers indicated as "Reserved" in the above table are for future expansion and to cater to new types of systems developed in the future.

+ SFRM denotes Spray-Applied Fire Resistive Materials

View the UL Guide Information for Fire Resistance Designs (BXUV).

View the UL Guide Information for Fire Resistance Designs Certified for Canada (BXUV7).

How to use this table to find UL Fire Resistance Design No.:

If you know the exact Fire Resistance Design Number you require, enter this number (e.g., U351, P907, X520) in the available Design No. field and click "Search".

If you do not know the exact Design Number, use the above Numbering System to refine your search options by following these steps:

  1. Choose the type of construction (i.e. column, wall, roof-ceiling, etc) from the first column, "Groups of Constructions". This will determine the alpha component necessary for your search (i.e. A, U, X, etc.)
  2. Follow along the respective row until you find the type of Protection (i.e. gypsum board, SFRM, masonry, unprotected, etc.) applicable to your construction then proceed to the top of that column to obtain the numeric components (range of numbers) necessary for your search (i.e. 400-499, 500-599, etc.).
  3. In the Fire Resistive Design search field, enter the alpha numeric component followed by the first number in the numeric component, then the wildcard * (i.e. U4*, X5*, etc.).
  4. Click Search.
  5. The search results will provide all Fire Resistive Design Numbers in the range provided (i.e. U400 . U499). Choose to view each Design individually by clicking the link in the "Link to File" column or choose to "Refine Your Search"
  6. Refine your search using key words such as 2 hr, vapor barrier, or recessed light.